Patent No. GC-0011850 — GCC Central Patent Office
Architects & Consultants

Specify with
confidence.

Guide specification, accredited test evidence and technical documentation for architects, facade consultants and main contractors.

Why This Page Exists

Everything you need to write us into the spec.

On a facade package the specification is written long before a subcontractor is appointed. This page gives design consultants the evidence and the wording to do that — without a sales conversation first.

At a Glance
  • Eight accredited tests, all passed, on one full-scale specimen
  • Air leakage measured 5× better than ASTM E283 permits
  • GCC Patent GC-0011850, valid to 2037, all six member states
  • Installed from inside the building — no scaffolding or cradles
  • Facade stays off the project critical path
Documentation Library

What we publish, and what we release on request.

Performance evidence is public. Detailed engineering documents are released to named consultants and contractors working on an identified project — not as open downloads.

System Performance Data Sheet
Accredited test results, patent, system range, installation method.
PublicDownload PDF
Guide Specification — Section 08 44 13
Editable three-part CSI specification for your project spec book.
PublicDownload Word
Accredited Test Report QK141
Full eight-test report, Thomas Bell-Wright International Consultants.
On requestRequest
U-Value Calculation
Frame and edge-seal thermal simulation to EN ISO 10077.
On requestRequest
System Drawings & Typical Details
Sections, anchorage and interface details for design development.
On requestRequest
Patent Certificate GC-0011850
Full GCC patent grant document.
On requestRequest
Structural Calculation
Project-specific calculation under your wind loads.
Project-specificRequest
Guide Specification

Section 08 44 13
Glazed Aluminium Curtain Walls

A three-part CSI MasterFormat guide specification, written to be edited. Bracketed notes are guidance to the specifier and should be deleted before issue.

Download editable Word file Request supporting documents
Note to the specifier. Performance values quoted below are the accredited results for the tested specimen. Project performance must be confirmed by project-specific calculation against your wind loads, glass make-up and elevation geometry.
PART 1 — GENERAL
1.1  SUMMARY
  • Section includes: aluminium curtain wall system, factory-finished and supplied pre-sized to installation dimensions, complete with glazing, gaskets, integrated drainage, anchors and perimeter closures.
  • Related sections: cast-in-place concrete and structural steel for anchorage substrate; sealants; glass and glazing where specified separately.
1.2  REFERENCES
  • ASTM E283 — Air leakage through exterior windows, curtain walls and doors.
  • ASTM E331 — Water penetration by uniform static air pressure difference.
  • ASTM E330 — Structural performance by uniform static air pressure difference.
  • AAMA 501.1 — Water penetration using dynamic pressure.
  • EN ISO 10077-1 and -2 — Thermal performance of windows, doors and shutters.
  • EN ISO 6946 — Building components: thermal resistance and transmittance.
  • AAMA 2605 — High performance organic coatings on architectural aluminium.
1.3  PERFORMANCE REQUIREMENTS
  • Air infiltration: when tested to ASTM E283 at 300 Pa, air leakage shall not exceed 24.95 m³/hr for the tested specimen area. [The UCS system was measured at 4.82 m³/hr — more than five times better than this limit.]
  • Static water penetration: no uncontrolled water on the interior face when tested to ASTM E331 at a static pressure of not less than 720 Pa for 15 minutes.
  • Dynamic water penetration: no uncontrolled water on the interior face when tested to AAMA 501.1 at not less than 720 Pa with a wind generator.
  • Structural performance: when tested to ASTM E330 at design wind load, deflection shall not exceed the limits set by the project structural criteria, with no permanent deformation.
  • Structural proof load: no failure of any component when tested to ASTM E330 at 1.5 × design load.
  • Sequence: air and water tests shall be repeated after structural loading on the same specimen and shall be re-passed.
  • Thermal transmittance: frame and edge-seal U-values shall be determined by two-dimensional numerical simulation to EN ISO 10077-1 and -2 with boundary conditions per EN ISO 6946. Project U-values shall be confirmed by project-specific calculation.
1.4  SUBMITTALS
  • Product data for each system component.
  • Shop drawings: elevations, typical and non-typical sections, anchorage details, movement joints, interfaces with adjacent construction.
  • Structural calculations for the system under project wind loads, signed by a qualified engineer.
  • Thermal calculation for the specified configuration.
  • Accredited test reports from an ISO/IEC 17025 laboratory for the test sequence in 1.3.
  • Samples: finish samples on the specified alloy; a corner assembly sample on request.
  • Warranty documentation.
1.5  QUALITY ASSURANCE
  • System supplier: the system shall be a proprietary, patented curtain wall system tested as a complete assembly on a single full-scale specimen, not an assembly of unrelated components.
  • Accredited testing: test reports shall be issued by a laboratory holding ISO/IEC 17025 accreditation recognised in the project territory.
  • Installer: a contractor approved in writing by the system supplier and trained in the system's installation method.
  • Mock-up: provide a visual mock-up for approval of finish, sightline and workmanship before fabrication release, where required by the project.
1.6  WARRANTY
  • Provide the manufacturer's standard system warranty against defects in materials and fabrication.
  • Provide the finish warranty applicable to the specified coating system.
  • Warranty periods shall be confirmed with the system supplier for the specific project.
PART 2 — PRODUCTS
2.1  MANUFACTURER
  • Basis of design: UCS Green System, UCS Green Solutions LLC, Dubai, United Arab Emirates. GCC Patent GC-0011850.
  • Profiles are extruded exclusively for this system by Emirates Extrusion Factory, Dubai.
  • Substitutions: proposed alternatives shall demonstrate, by accredited test reports on a single full-scale specimen, compliance with every performance requirement of Article 1.3, including the repeat air and water tests after structural loading.
2.2  SYSTEM TYPES
  • 4-Way Structural Glazing — four-edge structural bonding; no fastener penetrates the glass.
  • 2-Way Structural Glazing — two-edge structural bonding.
  • Conventional Curtain Wall — pressure-plate system accepting glass, aluminium composite panel, honeycomb panel, stone and marble on a single mullion and transom grid.
  • Strip Windows — banded horizontal window runs integrated with curtain wall on the same elevation.
  • Thermal Break Windows and Doors — polyamide-strip insulated; casement, sliding, pivot, fixed, swing and louvre.
  • Sun Breaker Systems — solar shading integrated into the profile grid without secondary framing.
  • Hand Rail and Balustrade — structurally engineered aluminium railing with glass, cable or solid panel infill.
2.3  MATERIALS
  • Aluminium: extruded aluminium alloy and temper as required to satisfy the structural performance of Article 1.3, confirmed by calculation.
  • Thermal break: polyamide insulating strip, mechanically locked into the profile.
  • Glass: as scheduled by the project. Coordinate glass thickness, make-up and edge treatment with the system supplier before order.
  • Gaskets and seals: extruded elastomeric gaskets compatible with the specified sealants and glazing.
  • Fasteners and anchors: non-corrosive; isolated from dissimilar metals.
  • Finish: powder coat or anodised as scheduled. Powder coating to AAMA 2605 where a superior-durability finish is specified.
2.4  FABRICATION
  • Profiles shall be extruded to exact installation dimensions and delivered directly to site. Cutting, drilling and fabrication of system profiles on site or in a site workshop shall not be required.
  • Drainage channels shall be engineered into the profile geometry. Reliance on applied sealant as the primary drainage or weathering line is not acceptable.
  • Provide for thermal movement, structural movement and construction tolerance without stress on the glass or loss of weather integrity.
PART 3 — EXECUTION
3.1  EXAMINATION
  • Verify that structural openings, slab edges and anchorage substrates are within the tolerances required by the approved shop drawings before installation.
  • Report unacceptable conditions in writing. Do not proceed until they are corrected.
3.2  INSTALLATION
  • The system shall be capable of installation entirely from inside the building, without scaffolding, suspended cradles or climber platforms.
  • Installation may proceed floor by floor concurrently with the concrete structure so that the facade does not sit on the project critical path.
  • Install plumb, level and true to line within the tolerances of the approved shop drawings.
  • Fabrication and installation deviations shall be correctable in place, without replacement orders.
  • Install in accordance with the system supplier's written instructions and under the supplier's technical supervision.
3.3  FIELD QUALITY CONTROL
  • Where required by the project, carry out field water testing to AAMA 501.2 on completed areas.
  • The system supplier shall be given access to inspect the works and to issue a written installation report.
3.4  PROTECTION AND CLEANING
  • Protect finished surfaces from damage and from contact with cementitious materials for the duration of the works.
  • Clean exposed surfaces in accordance with the finish manufacturer's recommendations before handover.

Need something that isn't here?

Test reports, U-value calculations, system drawings and project-specific structural calculations are all available to design teams on request.